25 w single output swipower supply
Product Detailed
Related Categories:Switching Power Supply
Detailed Product Description
MODEL | S-25-5 | S-25-12 | S-25-15 | S-25-24 | |
OUTPUT | DC VOLTAGE | 5V | 12V | 15V | 24V |
RATED CURRENT | 5A | 2.1A | 1.7A | 1.1A | |
CURRENT RANGE | 0 ~ 5A | 0 ~ 2.1A | 0 ~ 1.7A | 0 ~ 1.1A | |
RATED POWER | 25W | 25.2W | 25.5W | 26.4W | |
RIPPLE & NOISE (max.) Note.2 | 50mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | |
VOLTAGE ADJ. RANGE | 4.75 ~ 5.5V | 10.8 ~ 13.2V | 13.5 ~ 16.5V | 21.6 ~ 26.4V | |
VOLTAGE TOLERANCE Note.3 | ±2.0% | ±1.0% | ±1.0% | ±1.0% | |
LINE REGULATION | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
LOAD REGULATION | ±1.0% | ±0.5% | ±0.5% | ±0.5% | |
SETUP, RISE TIME | 300ms, 50ms/230VAC 800ms, 50ms/115VAC at full load | ||||
HOLD TIME(TYP.) | 90ms/230VAC 12ms/115VAC at full load | ||||
INPUT | VOLTAGE RANGE | 85 ~ 264VAC 120 ~ 370VDC | |||
FREQUENCY RANGE | 47 ~ 63Hz | ||||
EFFICIENCY (Typ.) | 72%/115VAC | 76%/115VAC | 77%/115VAC | 80%115VAC | |
AC CURRENT(Typ.) | 0.6A/115VAC 0.35A/230VAC | ||||
INRUSH CURRENT(max.) | COLD START 13A/115VAC 25A/230VAC | ||||
LEAKAGE CURRENT | <0.75mA / 240VAC | ||||
PROTECTION | OVERLOAD | 105 ~ 150% rated output power | |||
Protection type : Hiccup mode, recovers automatically after fault condition is removed. | |||||
OVER VOLTAGE | 5.75 ~ 6.75V | 13.8 ~ 16.2V | 17.25 ~ 20.25V | 27.6 ~ 32.4V | |
Protection type : Hiccup mode, recovers automatically after fault condition is removed. | |||||
ENVIRONMENT | WORKING TEMP. | -10 ~ +60 (Refer to output load derating curve) | |||
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | ||||
STORAGE TEMP., HUMIDITY | -20 ~ +85 , 10 ~ 95% RH | ||||
TEMP. COEFFICIENT | ±0.03%/ (0 ~ 50) | ||||
VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes | ||||
SAFETY & EMC (Note 4) | SAFETY STANDARDS | Design refer to UL1012, TUV EN60950-1 | |||
WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC | ||||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC | ||||
EMI CONDUCTION & RADIATION | Compliance to EN55022 (CISPR22) Class B | ||||
HARMONIC CURRENT | Compliance to EN61000-3-2,-3 | ||||
EMS IMMUNITY | Compliance to EN61000-4-2,3,4,5; ENV50204, EN55024, Light industry level, criteria A | ||||
OTHERS | MTBF | 330.8K hrs min. MIL-HDBK-217F (25) | |||
DIMENSION | 99*97*36mm (L*W*H) | ||||
PACKING | 0.35Kg; 60pcs/21.5Kg/0.57CUFT | ||||
NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. | ||||
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. | |||||
3. Tolerance : includes set up tolerance, line regulation and load regulation. | |||||
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives |